Professional chimney service

Pellet Stove Repair in Gardena

Have a Mason Look

Mortar Matched to the Brick
Written Quote Before Work
Photos With Every Report
Crowns Cast in a Form
NFPA 211 Inspection Levels
Based in Gardena
Mortar Matched to the Brick
Written Quote Before Work
Photos With Every Report
Crowns Cast in a Form
NFPA 211 Inspection Levels
Based in Gardena

What the Job Covers

Pellet stoves fail in their moving parts and their sensors. We test the feed motor, the igniter, both fans and the control board in turn, and replace only the one that failed. We also follow the vent pipe to where it exits, because a vent through brick or block needs a sealed thimble, and a cracked one lets exhaust into the wall. Repairs are quoted in writing with the parts listed.

Feed motor, igniter and fans tested in turn
Control board and sensors checked
Vent pipe cleaned out to the exterior cap
Thimble through brick or block inspected
Only the failed part replaced

Following the Fault Through the Stove

When a pellet stove stops, the symptom points to a stage. Fuel moves from the storage bin down a screw into the firepot. An igniter heats the pellets until they catch. A draft blower draws air in through the burning pellets and sends the smoke outside, while a second fan pushes warm air into the room. Switches and sensors watch temperature and pressure, and the controller halts everything if any of them reads wrong. So a stove that clicks and hums but never makes flame usually has an ignition or feed problem. One that lights and dies after a few minutes often has a vacuum switch reading a blocked vent, or a firepot so clogged with clinker that air cannot get through. One that runs but throws little heat may have a dirty heat exchanger or a tired room fan. We run the stove through its start and watch what it does at each stage before we pull a single part.

Many repairs are cleaning in disguise. Pellets leave fine ash and hard clinker, especially cheaper fuel with more bark and dirt in it, and that residue packs into the firepot holes, the passages behind the fire and the vent. A stove that has gone a season without a full clean will often run properly again once those are cleared. When a part has failed, it is usually one of a short list: the igniter, the feed motor, a blower motor, a switch, or the board. We test the suspect part before ordering it, since a dead igniter and a dead board can look the same from the front of the stove. Some older stoves need parts that have gone out of production; you hear about that at the start, with a sense of whether a replacement stove makes more sense. The brand plate is usually on the back panel or under a side cover, and having it to hand when you call saves time.

Where the Vent Meets the Masonry

A pellet stove vents through a small pipe, either straight out through an outside wall or up through an existing chimney. Both routes involve our trade. Where the pipe passes through a brick or block wall, it runs through a thimble, a sleeve that keeps the hot pipe off the masonry and closes the hole. Old mortar around that sleeve cracks and lets rain into the wall and cold air into the room. Where the stove vents up an old masonry chimney, the pellet pipe should continue as a liner all the way up the flue, sealed at the top. A pellet vent that simply ends a few feet inside an old flue lets exhaust and fine ash collect in a space far too big for it, and the stove struggles to draft. We check both, and point or seal around the thimble or fit a proper liner where the venting needs it.

Ash in the vent is the other half of the story. Pellet exhaust carries fine fly ash, and the horizontal runs and tees of a pellet vent collect it until the stove's pressure switch shuts it down. Clearing the vent is part of every repair visit, because there is no point fixing a stove that will choke again in a month. On a house in Compton or Inglewood where the vent runs out through a side wall, that means opening the cleanout tee and brushing back toward the stove. Where it runs up a chimney, it means working from the roof. Once the stove is repaired and the vent clear, we run it through a full cycle, check that it lights, settles and shuts down as designed, and write down what we replaced. If the visit shows the chimney or the wall around the vent needs masonry work, that is priced on its own.

The Nugent Chimney Care Way of Working

Mortar Tested

Old joints scratched before a mix is chosen

Brick Matched

Replacement units picked for size and tone

Quote on Paper

Each repair priced before work begins

Photos at the End

Finished joints and crown photographed for you

Other Masonry and Chimney Jobs

Chimney Sweep

Soot and glaze lifted off the flue tiles, with a mason's eye on every joint the brush passes on its way up.

Read more

Chimney Inspection

A mason's read of the stack: brick faces, mortar joints, crown, flue tiles and cap, written up with photos.

Read more

Chimney Repair

Mortar, brick, crown and flue tile repairs matched to the original materials, so the patch does not turn into the next failure.

Read more

Fireplace Inspection

Firebox brick, refractory joints, damper frame, smoke chamber and hearth examined from the room, with photo notes.

Read more

Fireplace Repair

Firebrick relaid, refractory joints renewed, hearths reset and smoke chambers parged, using heat-rated materials throughout.

Read more

Chimney Level 2 Inspection

Recorded footage of each flue joint plus the brick in the attic and on the roof, for sales, quakes, fires and fuel changes.

Read more

Chimney Cap Installation

Stainless or copper caps fastened to a sound crown, so the hood keeps water off the tile and the brick beneath it.

Read more

Chimney Flashing Repair

Counter flashing set into a fresh saw cut in sound mortar, step pieces woven into the roofing, and the brick above checked for leaks.

Read more

Chimney Masonry Repair

Tuckpointing, brick replacement and crown work, with mortar matched to the age and hardness of your brick.

Read more

Chimney Rebuilds

Failed stacks taken down to firm masonry and relaid with matched brick, new flue tile and a cast crown.

Read more

Fireplace Cleaning

Firebox, hearth and brick face cleaned of ash and smoke staining, with the masonry checked for heat damage as we work.

Read more

Gas Fireplace Cleaning

Burner, pilot, logs and glass cleaned on gas units, and the firebox brick or panels behind them looked over.

Read more

Gas Fireplace Repair

Pilot, valve, igniter and control faults on gas fireplaces found with a meter, plus any heat damage to the masonry around them.

Read more

Fireplace Remodel

Brick, stone and tile surrounds laid by masons, with hearths and mantels set to the clearances your fireplace needs.

Read more

Fireplace Inserts

Wood or gas inserts fitted into a sound masonry firebox, with a stainless liner and the brick around them repaired first.

Read more

Wood Stove Repair

Baffles, firebrick, door gaskets and glass renewed on wood stoves, plus the hearth pad and flue connection checked.

Read more

Gas Logs

Ceramic log sets for masonry fireplaces, with burner and valve fitted once the firebox brick and flue pass a check.

Read more

Chimney Seismic Retrofit

Steel bracing, framing anchors or a lighter rebuilt top for brick chimneys that stand loose from the house.

Read more

Chimney Crown Repair

Crowns recast in reinforced mortar with an overhang, or sealed while the cracks are still fine, to keep water out of the brick.

Read more

Dryer Vent Cleaning

Lint cleared from the duct between dryer and wall vent, with the outside hood and its pass through the wall checked.

Read more

Chimney Liner Installation

Stainless or poured liners for clay flues with cracked tiles or open joints, so heat and gas stay off the brick.

Read more

Chimney Leak Repair

Water traced to its entry point in the brick, crown, cap or flashing, then the masonry repaired at the source.

Read more

Chimney Waterproofing

Breathable repellent applied to cleaned, repointed brick, so rain beads off while moisture inside can still escape.

Read more

Chimney Damper Repair

Throat dampers freed, rebuilt or reset in their masonry frame, or a top-mount damper fitted on the flue tile.

Read more

Chimney Chase Cover

Stainless covers bent to fit framed chimneys on factory-built fireplaces, with the wood structure underneath checked for rot.

Read more
Call (323) 529-8089